| Blister Copper | Input | Technosphere flow | 1160 kg | No | Version and reference information- Related flow
- ca87ab19-c076-4ccf-9cbd-b76cb932a880@01.01.001
- Process
- ca25338c-6e4a-4cf7-9578-a5fb48f86ef5@01.01.001
- Functional unit
- 1000 kg
- Public-display policy version
- portal-display-capability-policy.v2
|
|---|
| water | Input | Elementary flow | 0.00318 m3 | No | Version and reference information- Related flow
- 419682fe-60fb-4b43-be89-bf2824b51104@00.00.002
- Process
- ca25338c-6e4a-4cf7-9578-a5fb48f86ef5@01.01.001
- Functional unit
- 1000 kg
- Public-display policy version
- portal-display-capability-policy.v2
|
|---|
| Electricity, alternating current | Input | Technosphere flow | 1450.8 MJ | No | Version and reference information- Related flow
- 4d0361a3-56cc-45f9-aa42-bb9103285bf9@01.01.003
- Process
- ca25338c-6e4a-4cf7-9578-a5fb48f86ef5@01.01.001
- Functional unit
- 1000 kg
- Public-display policy version
- portal-display-capability-policy.v2
|
|---|
| Anode copper | Output | Technosphere flow | 1000 kg | Yes | Version and reference information- Related flow
- 23b431ee-f7a0-4788-b2e2-7361cd48d4ad@01.01.001
- Process
- ca25338c-6e4a-4cf7-9578-a5fb48f86ef5@01.01.001
- Functional unit
- 1000 kg
- Public-display policy version
- portal-display-capability-policy.v2
|
|---|
| carbon dioxide (fossil) | Output | Elementary flow | 28600 kg | No | Version and reference information- Related flow
- 08a91e70-3ddc-11dd-923d-0050c2490048@03.00.004
- Process
- ca25338c-6e4a-4cf7-9578-a5fb48f86ef5@01.01.001
- Functional unit
- 1000 kg
- Public-display policy version
- portal-display-capability-policy.v2
|
|---|
| Nitrogen oxides | Output | Elementary flow | 2.87 kg | No | Version and reference information- Related flow
- f79d0f8f-2b0e-49cb-bed0-b1ea0fbd8625@01.00.004
- Process
- ca25338c-6e4a-4cf7-9578-a5fb48f86ef5@01.01.001
- Functional unit
- 1000 kg
- Public-display policy version
- portal-display-capability-policy.v2
|
|---|
| Chemical Oxygen Demand | Output | Elementary flow | 0.00378 kg | No | Version and reference information- Related flow
- e57fc631-2c77-457a-aa30-be79e357792b@01.01.000
- Process
- ca25338c-6e4a-4cf7-9578-a5fb48f86ef5@01.01.001
- Functional unit
- 1000 kg
- Public-display policy version
- portal-display-capability-policy.v2
|
|---|
| Total Suspended Particulate | Output | Waste flow | 6.43 kg | No | Version and reference information- Related flow
- 435d78a4-6a6d-4637-95a5-059092198678@01.01.001
- Process
- ca25338c-6e4a-4cf7-9578-a5fb48f86ef5@01.01.001
- Functional unit
- 1000 kg
- Public-display policy version
- portal-display-capability-policy.v2
|
|---|
| Suspended solids in water | Output | Technosphere flow | 0.00128 kg | No | Version and reference information- Related flow
- 667d9179-f50f-431f-8482-6b4b22d56f80@01.01.002
- Process
- ca25338c-6e4a-4cf7-9578-a5fb48f86ef5@01.01.001
- Functional unit
- 1000 kg
- Public-display policy version
- portal-display-capability-policy.v2
|
|---|